When
setting the height of the key joint allow the appropriate
set down distance. KJRM 12 x 12 = 14mm KJRM 20 x 10 =
12mm
|
Ensure clip section of Rebate Mould
is on the correct side to clip over the rolled edge of the
key joint. Push the Rebate Mould firmly onto the top of the
key joint.
|
Place the reinforcement and pour concrete
evenly to both sides of the key joint and finish surface to the top of the Rebate
Mould (NOT ABOVE IT). Always pour concrete evenly to both sides
of the joint and ensure concrete is compacted into the keyways.
|
When concrete has
cured sufficiently,
gently remove the top section of the Rebate Mould.
|
A "bond breaker" backing
tape should be applied to the bottom of the exposed rebate
before sealants are applied.
Apply masking tape
to both sides of the joint before injecting the flexible sealant
or semirigid filler material. Smooth off excess sealant and
peel back masking tape immediately after applying sealant.
|