REMOVABLE PVC CAPPING

When setting the height of the key joint allow the appropriate set down distance
KJCAP = 3mm
KJCAPL = 6mm

Push the capping strip firmly on to the top of the key joint.

Place the reinforcement and pour concrete
evenly to both sides of the key joint and finish surface to the top of the capping (NOT ABOVE IT). Always pour concrete evenly to both sides of the joint and ensure concrete is compacted into the keyways.

When concrete has cured sufficiently, gently remove the capping strip.

Apply masking tape to both sides of the joint before injecting the flixible sealant. Smooth off excess sealant and peel back masking tape immediately after applying sealant.